Built-in amplifier, liquid absorbing paper not needed,usable with various liquids..
Benefits
Field of application
Point level switch for all liquids.Features and specifications
Measuring Principle | Vibration Liquids |
Characteristic / Application | Liquiphant M Density with Density Computer FML621 Temperature and Pressuremeasurement Modular housing concept wide range of process connections compact for compensation (option) |
Supply / Communication | Transmitter power supply (MUS) |
Ambient temperature | -50...70°C -50...60°C for hazardous applications |
Process temperature | 0...80°C (validity of accuracy data) -50...0°C /80...150°C (with reduced technical data) |
Process pressure absolute | 0...25bar >25...64bar (with reduced technical data) |
Wetted parts | 316L/C4 |
Sensor length | Compact: 50,5mm |
Output | Pulse |
Certificates / Approvals | ATEX IECEx |
Specialities | Commissioning with ReadWin2000 |
Components | Density Computer FML621 |
Other approvals and certificates | SIL2/ SIL3 |
Measuring Principle | Vibration Liquids |
Characteristic / Application | Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g. Ex,WHG) compact, e.g. pipes |
Specialities | Foamdetection Detekt a densitychange second line of defense |
Supply / Communication | PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC or 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Ambient temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
Process pressure absolute / max. overpressure limit | Vacuum...64 bar (Vacuum...928 psi) |
Min. density of medium | 0.5g/cm³(0.4g/cm³ option) |
Main wetted parts | 316L, Alloy |
Process connection | Thread: G3/4A, G1A, R3/4", R1, NPT3/4, NPT1 Flange: DN25...DN100, ASME 1"...4", JIS 25A...100A |
Process connection hygienic | Tri-Clamp ISO2852 |
Communication | PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC or 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Safety approvals | Overfill prevention WHG SIL2/ SIL3 |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 AD2000 |
Marine approval | GL/ ABS |
Options | Heavy duty stainless steel housing mainly for the oil and gas industry |
Components | FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |